Carefully check engine oil or engine coolant passages for any restriction and blockage. Using scraper, remove old liquid gasket adhering to the gasket application surface and the mating surface. Apply liquid gasket without breaks to the specified location with the specified dimensions.
While securely holding the square hole (A) in pulley center of auto tensioner (1) with a spinner handle, move spinner handle in the direction of arrow (loosening direction of drive belt). Remove clips, and slide air duct (inlet) frontward, disengage clips and air cleaner case. Remove air cleaner case/mass air flow sensor assembly and air duct assembly disconnecting their joints.
When engine coolant is not drained from radiator, attach plug to water hoses to prevent engine coolant leakage. N Viewed from the air duct side, order of loosening mounting bolts of electric throttle control actuator (bank 2) is the same as that of the electric throttle control actuator (bank 1). Loosen mounting bolts with power tool in reverse order as shown in the figure to remove intake manifold collector.