Manual Description
Push the odo/trip meter switch at least 3 times within 7 seconds after the ignition switch is turned ON. The unified meter control unit is turned to self-diagnosis mode. Each meter/gauge should indicate as shown in the figure.
Check voltage between combination meter harness connector M24 terminals 1, 2, 14 and ground. Check continuity between combination meter harness connector terminals 3, 4, 23 and ground. Check voltage between combination meter harness connector M24 terminal 35 and ground.
Disconnect combination meter connector and seat belt buckle switch LH connector. Check harness continuity between combination meter harness connector M24 terminal 35 and ground. Disconnect the seat belt buckle switch LH connector.
Manual Cover
General