Manual Description
The voltage output is controlled by the IC regulator. Used for the power generation voltage variable control system. By varying the voltage to the generator, H engine load due to power generation of the generator is reduced and fuel consumption is decreased.
Refer to the applicable Instruction Manual for proper testing procedures. NO >> Replace the blown fuse or fusible link after repairing the affected circuit. Malfunction detected>> Check applicable parts, and repair or replace corresponding parts.
Check continuity between generator harness connector and ground. Refer to applicable Instruction Manual for proper testing procedures. NO >> Check harness for open between generator and fusible link.