Manual Description
When the shift lever is shifted to the reverse position, the construction allows smooth shift operation by stopping the reverse idler shaft rotation by frictional force of synchronizer. Fill with new oil until oil level reaches the specified limit at filler plug hole as shown. Do not perform tapping by other than screwing tapping bolt because tapping is formed by screwing tapping bolt into clutch housing.
Disconnect air breather hose clips and disconnect air breather hose from resonator. Differential side bearing inner race race (transaxle case side) (transaxle case side) I 4. Remove drain plug and gasket from clutch housing, using a suitable tool and then drain gear oil.
Remove selector lever (1) retaining pin with a pin punch to L remove selector lever. Remove transaxle case (2) while rotating shifter lever A (1) in the direction as shown. Shift 1st-2nd fork rod (1), fork rod (2), and reverse fork rod (3) to the neutral position.