This condition may cause a malfunction of the engine control system and battery discharge may occur. Do not connect an electrical component or ground wire directly to the battery terminal. The voltage output is controlled by the IC regulator.
Used for the power generation voltage variable control system. By varying the voltage to the generator, engine load due to power generation of the generator is reduced and fuel consumption is decreased. Check continuity between generator harness connector E122 (A) terminal 4 and ground.
Confirm repair by performing complete Starting/Charging system test. NO >> Check harness for open between generator and fusible link. Check voltage between battery positive terminal and generator connector E204 terminal 1.